Black Friday

Blekk & Toner guide

 



 

Du er her // Forsiden // //
D-LINK
REDUNDAND PS 60 WATT RPSU

D-LINK REDUNDAND PS 60 WATTRPSU

REDUNDAND PS 60 WATT RPSU
Varenr: DPS-200
Lagerstatus: Ingen på lager for øyeblikket
Frakt: 79,- Sjekk din fraktpris
Frakt
Fyll inn postnummer og klikk
knappen for å vise fraktpriser
  Vis priser
2 792,-  inkl. mva
Fra 202,-/mnd (20 mnd)
Utsett betalingen i 4-6 mnd
Velg finansiering i kassen
Kjøp
Produktinfo

The tandem of D-Link’s new Enterprise Gigabit switches and DPS Series of Modular Redundant Power Supplies (RPSU) enables today’s business networks with unmatched flexibility, performance, scalability, and availability.
The modular design of the DPS Series of RPSUs enables companies to selectively and cost effectively deploy higher availability configurations precisely when and where they are needed most. When paired with a supported D-Link switch, the DPS-200, and DPS-500 provide uninterrupted fail-over, in the unlikely event of a mechanical power supply failure. The system integration between D-Link’s Managed Layer 2 switches, Layer 3 switches, and RPSU system, provide customers with the fundamental building blocks to create economical and scalable networks without having to sacrifice network performance and availability.

  DPS-200      60Watt Redundant Power Supply Unit (Includes RPSU Cable and AC Power Cord)
  DPS-500      140Watt Redundant Power Supply Unit (Includes RPSU Cable and AC Power Cord)
  DPS-800       (2) Slot, 1U, 19 inch Rackmounting Chassis For DPS-200, DPS-300, and/or DPS-500 Units
  Hold Up Time       16ms at Max Load and 115VAC Input at 60Hz Output Drop Down to 95% Voltage
  Efficiency       75% Min. At Max Load and 115VAC Input
Input Specifications
  AC Input Voltage Rating       100VAC to 240VAC
  AC Input Voltage Range       90VAC to 264VAC
  AC Input Frequency       47Hz to 63Hz
  Max. In-Rush Current       30A Max @ 115VAC, 60A Max @ 230VAC at 25° Ambient Cold Start
  Max Input Current (DPS-200)       1.6A Max For 115VAC & 0.8A Max For 230VAC
  Max Input Current (DPS-500)       4.0A Max For 115VAC & 2.0A Max For 230VAC
Output Specifications
  Output Voltage       +12V
  Min. Load Current      0.5A
  Max Load Current       5.0A
  Line Regulation       (+/-) 2% Measured Output Load From (+/-) 10% Rated Load
Physical & Environmental
  Safety       UL and/or CSA
  Dimensions RPSU (WxDxH)       (6.69 x 7.48 x 1.77 inches) RPSU Units
  Dimensions Chassis (WxDxH)       (19.06 x 7.09 x 2.17 inches) DPS-800 Chassis
  Weight RPSU       (2.2 lbs) Weight Is Without DPS-800 Chassis
  Weight Chassis       (2.0 lbs) Weight Is Without RPSU Units
  Temperature       Operating: 0° - 40° C (32° - 104° F)
  Storage       -25° - 55° C (-13° - 131° F)
  Humidity       Operating: 20% to 80% RH, Non-Condensing
Warranty and Support Information
  Warranty      Power Supplies and Fans Carry A Limited 1 Year Warranty.
  Support       Free Technical Support
Ordering Information
  Part Number      Description
  DPS-200       60Watt Redundant Power Supply Unit (Includes RPSU Cable and AC Power Cord)
  DPS-500      140Watt Redundant Power Supply Unit (Includes RPSU Cable and AC Power Cord)
  DPS-800       (2) Slot, 1U, 19 inch Rackmounting Chassis For DPS-200, DPS-300 and/or DPS-500 Units