InRow RC 300mm Chilled Water

APC InRow RC 300mm ChilledWater

Varenr: ACRC301H
Lagerstatus: Forventet 08.11.2016
Frakt: 79,- Sjekk din fraktpris
Fyll inn postnummer og klikk
knappen for å vise fraktpriser
  Vis priser
84 769,-  inkl. mva

InRow Chilled Water Cooling


Close-coupled, chilled water cooling for medium to large data centers

Includes: Installation guide, Operations and maintenance manual

  • Allows system to remain operational if a fan replacement is required.
  • Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.
  • Notifies user in the event of a water leak within the coiling unit.
  • Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
  • Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
  • Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
  • Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Draws power from the UPS for power protection with dual feeds for redundancy.
  • Rack inlet control guarantees inlet temperature to IT equipment.
  • Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
  • Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Modular design provides scalable solutions to add cooling as demand increases.
  • Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Provides flexibility to move the unit to wherever cooling is required.
  • Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Real-time display of current and available cooling.
  • Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
  • Send alarms and data points allowing you to manage critical building infrastructure from a single system.


Air Discharge Patterns
Intake Air
Rear Return
Air Flow
1982.18 lps
Minimum Water Inlet Temperature
7.0 °C
Number of Power Cords
Number of Power Feeds
Nominal Input Voltage
208, 220, 230
Input Power
1900 Watts
Minimum Circuit Amp Capacity
Input Frequency
50/60 Hz
Maximum Overcurrent Protection
Rack Height
Input Connections
Hard Wire 3-wire
Communications & Management
Control panel
Multi-function LCD status and control console
Audible Alarm
Audible and visible alarms prioritized by severity
Interface Port(s)
Input contact closure
Maximum Height
1991.00 mm
Maximum Width
300.00 mm
Maximum Depth
1095.00 mm
Net Weight
162.73 KG
Shipping Weight
193.41 KG
Shipping Height
2118.00 mm
Shipping Width
746.00 mm
Shipping Depth
1137.00 mm
Units per Pallet
Regulatory Approvals
C-tick, CE, EN 55022 Class A, EN 55024, EN 60950, GOST, IEC 60950, IEC 61000-3-2, IEC 61000-3-3, MEA, VDE
Standard Warranty
1 year (parts only)
Sustainable Offer Status
REACH: Contains No SVHCs
Available in Documentation tab
Available in Documentation tab
Battery Directive
Battery Notes
Contains Lithium Coin Cell
Other Environmental Compliance
China RoHS